Location connection detail fields

Validation rules for fields related to connection details for a location.

Verisk Synergy Studio's individual risk methodology follows a structured, logical approach that groups building characteristics (SRCs) that are supported in a specific model. Refer to the "Secondary Risk Characteristics Matrix"—https://risksolutions.verisk.com/models/landing-pages/secondary-risk-characteristics/—which is available on the landing page on the Client Portal (login required)—that serves as a guide to the SRCs supported by each model. The landing page includes peril-specific SRC documentation. Users may also refer to a model's detailed description (available on the Client Portal).

Use the following links to get information about Location Building Detail fields, such as floor of interest and floor area, and about Location Surrounding Detail fields, such as pounding and tree exposure.

Secondary risk characteristic Supported country / peril Description Validation rules Default value
Roof Attached Structure
  • HI-TC
  • US ST
  • US TC
Types of mechanical and other equipment that are attached to the roof of a building:
  • Unknown/default (0)
  • Chimneys (1)
  • A/C Units (2)
  • Skylights (3)
  • Parapet Walls (4)
  • Overhang/Rake (8-36 in., null) (5)
  • Dormers (6)
  • Other (7)
  • No Attached Structures (8)
  • Overhang/Rake (< 8 in., null) (9)
  • Overhang/Rake (> 36 in., null) (10)
  • Waterproof membrane/fabric (11)
  • Secondary water resistance - Yes (12)
  • Secondary water resistance - No (13)
  • Optional
Unknown/default (0)
Transition in SRC Type JP EQ Indicates whether the transition from steel-reinforced concrete (SRC) to reinforced concrete (RC) in the columns of a building with SRC construction is smooth:
  • Unknown/default (0)
  • Smooth (1)
  • Non-smooth (2)
Optional
Cold Formed Tube JP EQ Indicates the presence of cold-formed tubes in a building:
  • Unknown/default (0)
  • No (1)
  • Yes (2)
Optional
Column Basement Type JP EQ The type of connection between the columns and basement in a building with steel-reinforced concrete (SRC) or steel construction:
  • Unknown/default (0)
  • Mixed (1)
  • Non-Embedded (2)
  • Embedded (3)
Optional
Welding Detail JP EQ Indicates whether welding occurs in a building:
  • Unknown/default (0)
  • On-Site (1)
  • In-House (2)
Optional
Foundation Connection
  • CA EQ
  • HI EQ
  • HI TC
  • JP EQ
  • NZ EQ
  • US EQ
  • US ST
  • US TC
Types of connection between a structure and foundation:
  • Unknown/default (0)
  • Hurricane ties (1)
  • Nails/Screws (2)
  • Anchor Bolts (3)
  • Gravity/Friction (4)
  • Adhesive/Epoxy (5)
  • Structurally Connected (6)

For industrial facilities: One of the following values to describe the anchorage of equipment at the facility:

  • Unknown/default (0)
  • Unanchored (4)
  • Anchored (6)
  • Optional
  • For Verisk Earthquake Model for the United States, you must specify Gravity/Friction (4) if you want to use the Retrofit Measures option Foundation anchorage (bolting) (4).
Foundation Type
  • CA EQ
  • CA IF
  • CEU IF
  • EU ETC
  • HI EQ
  • IT IF
  • JP IF
  • JP EQ
  • JP TY
  • MY/ID IF
  • NZ EQ
  • SK TY
  • UK/ROI IF
  • US EQ
  • US IF
  • US TC
The types of building foundations:
  • Unknown/default (0)
  • Masonry basement (1)
  • Concrete basement (2)
  • Masonry wall (3) No longer supported. If you use this value, the application maps it to Crawlspace cripple wall (4) (wood) upon import.
  • Crawlspace cripple wall (4) (wood)
  • Crawlspace masonry (5) (wood)
  • Post & pier (6)
  • Footing (7)
  • Mat / slab (8)
  • Pile (9)
  • No basement (10)
  • Engineering foundation (11)
  • Crawlspace - raised (wood) (12)
  • Optional
  • The application does not validate this field.
Internal Partition
  • CA EQ
  • HI EQ
  • JP EQ
  • US EQ
Types of interior walls:
  • Unknown/default (0)
  • Wood (1)
  • Gypsum boards (2)
  • Plastered masonry (3)
  • Brick (4)
  • Other (5)
Optional
Wall Attached Structure
  • HI TC
  • US TC
  • US ST
Types of structures that may be attached to a primary building:
  • Unknown/default (0)
  • Carports/Canopies/Porches (1)
  • Single Door Garages (2)
  • Double Door Garages (3)
  • Reinforced Single Door Garages (4)
  • Reinforced Double Door Garages (5)
  • Screened Porches/Glass Patio Doors (6)
  • Balcony (7)
  • No attached wall structures (8)
  • Wall-mounted A/C units (9)
Optional
Appurtenant Structure
  • HI TC
  • US TC
  • US ST
Types of appurtenant structures:
  • Unknown/default (0)
  • Detached garage (1)
  • Pool enclosures (2)
  • Shed (3)
  • Masonry boundary wall (4)
  • Other fence (5)
  • No appurtenant structures (6)
  • No pool enclosures (7)
Optional
Basement Level Count
  • CA IF
  • MY/ID IF
  • SEU IF
  • SK TY
  • UK/ROI IF
  • US IF
  • US TC
The number of basement levels in a building. A value of 0 represents Unknown/default.

If you specified an occupancy code of 301 - General Residential, 302 - Permanent dwelling: single family, or 303 - Permanent dwelling: multi family, the application supports only one level of basement. In these cases, if you input a larger value, it overrides this value with 1.

If the number of basement levels is greater than one, and if the foundation type is Masonry basement (1), then the application assumes that it is a concrete basement for all further purposes (since a masonry basement is assumed not to have more than one level of basement).

  • Optional
Basement Finish Type
  • CA IF
  • MY/ID IF
  • SK TY
  • UK/ROI IF
  • US IF
  • US TC
Indicates whether the basement is finished or unfinished:
  • Unknown/default (0)
  • Unfinished basement (1)
  • Finished basement (2)
  • Optional
  • You should use this field in conjunction with the Masonry basement (1) or Concrete basement (2) foundation type.
Deck
  • AU WF
  • US WF
Deck codes for a given location:
  • Unknown/default (0)
  • No Deck (1)
  • Deck: Unknown Construction (2)
  • Deck: Non-combustible Construction (21)
  • Deck: Combustible Construction (22)
Unknown/Default (0)
Gutter
  • AU WF
  • US WF
Information about a gutter:
  • Gutter - material/cover unknown (0)
  • Gutter with guard/cover (1)
  • Gutter without guard/cover (2)
  • No gutter (3)
Gutter - material/cover unkn (0)
Fences Within 5 ft
  • US WF
Information about fences:
  • Unknown (0)
  • No fences (1)
  • Non combustible (2)
  • Combustible (3)
  • Combustible - on the ground - unknown material (301)
  • Combustible - on the ground - plastic/software (3011)
  • Combustible - on the ground - hardwood (3012)
  • Combustible - elevated - unknown materials (302)
  • Combustible - elevated - plastic/softwood (3021)
  • Combustible - elevated - hardwood (3022)
Unknown (0)