Guidelines for Data Consistency with Property-Specific Database
The following tables describe how Data Quality Augment defines consistency of data with data in the AIR Property-specific database (PSD). Augment does not generate consistency statistics for all fields, such as for latitude, longitude, building replacement value, and gross area; if the data is inconsistent, Augment updates it.
|
PSD Attribute |
How Augment Defines Consistency |
|---|---|
|
Construction |
Is in the same general category, as specified in the construction categories listed in the Benchmark diagnostic |
|
Occupancy |
Is in the same general category, as specified in the occupancy categories listed in the Benchmark diagnostic. |
|
Year Built |
Exactly matches year built in the PSD. |
|
Stories |
Exactly matches stories in the PSD. |
|
Client Value |
Client Description |
Consistent PSD Values |
|---|---|---|
|
1 |
Flat |
1 |
|
2 |
Gable end without bracing |
2 or 8 |
|
3 |
Hip |
3 |
|
4 |
Complex |
4 |
|
5 |
Stepped |
5 |
|
6 |
Shed |
6 |
|
7 |
Mansard |
7 |
|
8 |
Gable end with bracing |
2 or 8 |
|
9 |
Pyramid |
9 |
|
10 |
Gambrel |
10 |
|
Client Value |
Client Description |
Consistent PSD Values |
|---|---|---|
|
1 |
Asphalt shingles |
1 |
|
2 |
Wooden shingles |
2 |
|
3 |
Clay or concrete tiles |
3 |
|
4 |
Light metal panels |
4 |
|
5 |
Slate |
5 |
|
6 |
Built-up roof with gravel |
6 or 9 |
|
7 |
Single-ply membrane |
7 or 10 |
|
8 |
Standing-seam metal roof |
8 |
|
9 |
Built-up roof without gravel |
6 or 9 |
|
10 |
Single-ply membrane ballasted |
7 or 10 |
|
11 |
Hurricane wind rated roof coverings |
Not applicable. Since Augment never replaces roof covering 11, it excludes them from augmentation. There are no "11" values in the PSD. |
|
Client Value |
Client Description |
Consistent PSD Values |
|---|---|---|
|
1 |
Veneer brick/masonry |
1 |
|
2 |
Wood shingles |
2 |
|
3 |
Clapboard |
3 |
|
4 |
Aluminum or vinyl siding |
4 |
|
5 |
Stone panels |
5 |
|
6 |
Exterior insulation finishing system |
6 |
|
7 |
Stucco |
7 |
|
Client Value |
Client Description |
Consistent PSD Values |
|---|---|---|
|
1 |
Masonry basement |
1 or 2 |
|
2 |
Concrete basement |
1 or 2 |
|
4 |
Crawlspace - cripple wall (wood) |
4, 5, or 12 |
|
5 |
Crawlspace - masonry (wood) |
4, 5, or 12 |
|
6 |
Post & pier |
6 |
|
7 |
Footing |
7 |
|
8 |
Mat or slab |
8 |
|
9 |
Pile |
9 |
|
10 |
No basement |
10 |
|
11 |
Engineering foundation |
11 |
|
12 |
Crawlspace - raised (wood) |
4, 5, or 12 |